Skip to main navigation Skip to search Skip to main content

A single-phase synchronization technique for grid-connected RESS under distorted grid conditions

Research output: Chapter in Book/Report/Conference proceeding › Conference contribution › peer-review

3 Citations (Scopus)

Abstract

The control of single-phase grid-connected Renewable Energy Storage System (RESS) requires a very fast and accurate estimation of grid voltage frequency and phase angle. A Phase-locked Loop (PLL) based synchronization algorithm usually extracts this information. The operation and control of entire system is directly affected by the performance of PLL. In this paper, a novel less complex Advanced Single-phase PLL (ASφPLL) technique has been proposed for the fast and accurate extraction of grid information in a battery storage system under distorted and abnormal grid conditions such as under harmonics, interharmonics, DC-offset and grid faults. The proposed method presents a faster dynamic response, lower frequency overshoot, and accurate estimation under off-nominal grid frequencies. More importantly, its computational complexity is very low. The advanced performance of the proposed ASφPLL is verified through simulation and experimental results.
Original languageEnglish
Title of host publication2019 IEEE Energy Conversion Congress and Exposition, ECCE 2019
PublisherInstitute of Electrical and Electronics Engineers (IEEE)
ISBN (Print)9781728103952
DOIs
Publication statusPublished - Nov 2019

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy

Cite this