An Analysis of the Development of Modular Building Design Elements to Improve Thermal Performance of a Representative High Rise Residential Estate in the Coastline City of Famagusta, Cyprus

Hasim Altan, Bertug Ozarisoy

Research output: Contribution to journalArticlepeer-review

15 Citations (Scopus)

Abstract

Passive design strategies can reduce heating and cooling demands with integration of more efficient building systems as well as the potential to integrate modular off-site construction technology and its technical systems to offset overall energy consumption. This study evaluates the energy performance of the nationally representative post-war social housing estate in the southeastern Mediterranean island of Cyprus where the weather is subtropical (Csa) and partly semi-arid (Bsh). This study employed a mixed methods research design approach which was based on a thorough field study that consisted of a questionnaire survey conducted with residents of the social housing estate in the hottest summer month of August, to explore the occupants’ thermal sensation votes (TSVs), their habitual adaptive behaviour, and home energy performance concurrently. On-site environmental monitoring was performed, and in-situ measurements of each occupied space were recorded to identify ‘neutral’ adaptive thermal comfort. The selected representative high-rise residential development was modelled using Integrated Environmental Solutions’ Virtual Environment (IES-VE) software, where extensive dynamic thermal simulations have been produced to assess existing energy performance and energy effectiveness of retrofitting strategies. The results demonstrated that a moderate–strong relationship was found between orientation and reasons for thermal discomfort (χ2 = 49,327, p < 0.001, Cramer’s V = 0.405). Individual levels of thermal comfort were not limited to household socio-demographic characteristics, however; environmental factors were also determinants in the development of adaptive thermal-comfort theory. Furthermore, the occupants’ TSVs indicated that in a southeastern Mediterranean climate, 28.5 °C is considered a neutral temperature, and the upper limit of the indoor-air thermal-comfort range is 31.5 °C.
Original languageEnglish
Article number4065
JournalMDPI Sustainability
Volume14
Issue number7
DOIs
Publication statusPublished - 29 Mar 2022

Bibliographical note

Publisher Copyright:
© 2022 by the authors. Licensee MDPI, Basel, Switzerland.

Keywords

  • building performance optimisation; passive cooling design; retrofit energy design; thermal comfort

Fingerprint

Dive into the research topics of 'An Analysis of the Development of Modular Building Design Elements to Improve Thermal Performance of a Representative High Rise Residential Estate in the Coastline City of Famagusta, Cyprus'. Together they form a unique fingerprint.

Cite this