Skip to main navigation Skip to search Skip to main content

An improved system for the automatic estimation of the Arteriolarto-Venular diameter Ratio (AVR) in retinal images

  • University of Padua
  • Department of Information Engineering

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

38 Citations (Scopus)

Abstract

The Arteriolar-to-Venular diameter Ratio (AVR), a parameter derived from vessel caliber measurements in a specific region of retinal images, is used as a descriptor of generalized arteriolar narrowing, an eye fundus sign often seen in patients affected by hypertensive or diabetic retinopathies. We developed an improved system to compute AVR in a totally automatic way. Images are at first enhanced to highlight the vessel network, which is then traced by a vessel tracking algorithm. From the detected vessel structure, the position of the optic disc is derived and the region inside which the AVR data are to be measured is determined. Vessels within this region are classified as either arteries or veins, their caliber is estimated and the AVR parameter is eventually computed. Improvements with respect to the previous version are related to post-processing algorithms to enhance vessel tracking and a totally new artery/vein discrimination technique. Results provided by the new system have been compared with manually derived AVR values on 20 eye fundus images, resulting in a final correlation coefficient of 0.88.

Original languageEnglish
Title of host publicationProceedings of the 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'08
PublisherIEEE Computer Society
Pages3550-3553
Number of pages4
ISBN (Print)9781424418152
DOIs
Publication statusPublished - 14 Oct 2008
Externally publishedYes
Event30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'08 - Vancouver, BC, Canada
Duration: 20 Aug 200825 Aug 2008

Publication series

NameProceedings of the 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'08 - "Personalized Healthcare through Technology"

Conference

Conference30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'08
Country/TerritoryCanada
CityVancouver, BC
Period20/08/0825/08/08

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Cite this