Application of Vacuum Insulation Panels in the cold chain - Analysis of viability

Edward Hammond, Judith Evans

Research output: Contribution to journalArticlepeer-review

43 Citations (Scopus)

Abstract

© 2014 Elsevier Ltd and IIR.Vacuum Insulation Panels (VIPs) have already found application in some specialist applications where minimal energy consumption is important and space is at a premium. This paper investigates the feasibility of widespread application of VIPs in the cold chain by embedding them into the polyurethane (PU) foamed walls of traditional refrigerator and freezer cabinets. Thermal modelling of the insulation of a range of typical refrigerator and freezer cabinets as used throughout the cold chain was carried out both with and without VIPs embedded in the insulating walls. The potential energy savings and payback times were then calculated; for refrigerators the average payback was 9.7 years, for freezers it was 4.5 years.
Original languageEnglish
Pages (from-to)58-65
JournalInternational Journal of Refrigeration
DOIs
Publication statusPublished - 28 Jul 2014

Keywords

  • 09 Engineering
  • Mechanical Engineering & Transports

Fingerprint

Dive into the research topics of 'Application of Vacuum Insulation Panels in the cold chain - Analysis of viability'. Together they form a unique fingerprint.

Cite this