Abstract
There is growing evidence that terraced houses—thermally lightweight, well insulated, naturally ventilated with three exposed wall surfaces—are at risk of overheating, especially in south-eastern England. The aim of this study is to evaluate the building performance and develop a reliable building simulation, which will be employed in the second phase of the study: developing affordable and feasible passive design strategies to support the energy-efficient building systems of the construction industry. This paper reports on the results from the first phase of the study where a quantitative methodology, including indoor and outdoor environmental monitoring, in-situ measurements and building simulation modelling, was adopted. The performance of a case study was modelled and simulated via employing Integrated Environmental Solutions (IES) software suite.
The results from the base-case were analysed according to the adaptive thermal comfort of Chartered Institution of Building Services Engineers (CIBSE) Technical Memorandum 52 guidelines: The Limits of Thermal Comfort—Avoiding Overheating in European Buildings. The spaces studied within the case study house were observed to exceed the acceptable limits of thermal comfort; particularly, the large bedroom within this zone exceeded the upper limit for overheating up to 11 h daily. Furthermore, the results from the monitoring study indicate a high risk of summertime overheating across all the case study settings, especially during short-term peaks in outdoor temperatures. The main reasons for the problematic thermal performance were identified as well-insulated and fully air-tight building fabric, the lack of sufficient ventilation through the living spaces and excessive heat gains through the composite cladding material.
The results from the base-case were analysed according to the adaptive thermal comfort of Chartered Institution of Building Services Engineers (CIBSE) Technical Memorandum 52 guidelines: The Limits of Thermal Comfort—Avoiding Overheating in European Buildings. The spaces studied within the case study house were observed to exceed the acceptable limits of thermal comfort; particularly, the large bedroom within this zone exceeded the upper limit for overheating up to 11 h daily. Furthermore, the results from the monitoring study indicate a high risk of summertime overheating across all the case study settings, especially during short-term peaks in outdoor temperatures. The main reasons for the problematic thermal performance were identified as well-insulated and fully air-tight building fabric, the lack of sufficient ventilation through the living spaces and excessive heat gains through the composite cladding material.
Original language | English |
---|---|
Pages (from-to) | 201-217 |
Number of pages | 17 |
Journal | Energy and Buildings |
Volume | 187 |
DOIs | |
Publication status | Published - 12 Feb 2019 |
Externally published | Yes |
Keywords
- Building performance
- Heat wave
- Overheating
- Retrofit
- Social housing
- Thermal comfort