Design and development of apparatus to provide repeatable surface temperature-time treatments on inoculated food samples

Research output: Contribution to journalArticlepeer-review

18 Citations (Scopus)

Abstract

The majority of data relating heat treatments to thermal death kinetics has previously been obtained by carrying out in vitro tests on small samples of microorganisms in growth medium or food slurries. However, strong evidence exists that suggests microbial death on heat-treated food surfaces cannot be predicted accurately from such systems. An apparatus was therefore designed to enable microbial death on food surfaces to be quantified. The apparatus uses hot air to provide a ‘dry’ heat treatment to raise the surface of a food sample to a given temperature, up to 100 °C, hold and then cool it. The surface temperature was measured using an infra-red (IR) thermometer and the air heater was controlled to give a specified surface temperature history. Steam was also used to provide a ‘wet’, but less controlled heating cycle.
Original languageEnglish
Pages (from-to)7-18
JournalJournal of Food Engineering
DOIs
Publication statusPublished - 21 Jul 2005

Keywords

  • surface decontamination
  • 0908 Food Sciences
  • surface temperature measurements
  • Food Science
  • microbial models
  • food poisoning
  • heating and cooling equipment

Fingerprint

Dive into the research topics of 'Design and development of apparatus to provide repeatable surface temperature-time treatments on inoculated food samples'. Together they form a unique fingerprint.

Cite this