Abstract
A photovoltaic system which enjoys water flow cooling to enhance the performance is considered, and the impact of water flow rate variation on energy payback period is investigated. The investigation is done by developing a mathematical model to describe the heat transfer and fluid flow. A poly crystalline PV module with the nominal capacity of 150 W that is located in city Tehran, Iran, is chosen as the case study. The results show that by increasing water flow rate, EPBP declines first linearly, from the inlet water flow rate of 0 to 0.015 kg.s-1, and then, EPBP approaches a constant value. When there is no water flow cooling, EPBP is 8.88, while by applying the water flow rate of 0.015 kg.s-1, EPBP reaches 6.26 years. However, only 0.28 further years decrement in EPBP is observed when the inlet water mass flow rate becomes 0.015 kg.s-1. Consequently, an optimum limit for the inlet water mass flow rate could be defined, which is the point the linear trend turns into approaching a constant value. For this case, as indicated, this value is 0.015 kg.s-1.
Original language | English |
---|---|
Pages (from-to) | 73-85 |
Journal | International Journal of Solar Thermal Vacuum Engineering |
DOIs | |
Publication status | Published - 25 Aug 2021 |
Externally published | Yes |
Keywords
- Parametric study
- Photovoltaic (PV) technology
- Energy payback period
- Water-flow cooling technique
- Efficiency improvement way