T1 - Evaluation of image based spatially variant and count rate dependant point spread functions on the HRRT PET scanner
AU - Kotasidis, Fotis A.
AU - Angelis, Georgios I.
AU - Henderson, Jack
AU - Buckley, Anna
AU - Markiewicz, Pawel J.
AU - Green, Michael
AU - Anton-Rodriguez, Jose
AU - Lionheart, William R.
AU - Reader, Andrew J.
AU - Matthews, Julian C.
PY - 2011/10/29
Y1 - 2011/10/29
N2 - Spatial resolution is of high importance especially in preclinical and brain PET imaging and characterization of the scanner's resolution properties requires measuring its point spread function (PSF). In our previous work we measured the PSF in 2 PET/CT scanners using a printed point source array. Here we extend the work to accurately measure the spatial variation of the PSF on the High Resolution Research Tomograph (HRRT) and assess the impact of the scanner's depth of interaction (DOI) capability on the spatial resolution. Furthermore we characterize the dependency of the PSF to count rate. An array of 15x11 printed sources was scanned twice, initially on its own (10min scan) and subsequently with an extension line containing ∼300MBq of carbon-11 at the scan starts (15 x 10min contiguous frames). Data were reconstructed with OP-OSEM and invariant PSF OP-OSEM. The PSF was found to be radially dependent in all directions but importantly radially symmetric and almost axially independent. The FWHM improves by ∼1.3mm using the PSF-OP-OSEM but is still radially variable with almost 1 mm degradation within the boundaries within which the brain is typically located. When DOI was not taken into account, a degradation up to 0.7mm was seen in the radial FWHM. In terms of count rate dependency, a clear resolution deterioration was seen, for count rates above 5-10 kcps with such count rates observed during many clinical scans.
AB - Spatial resolution is of high importance especially in preclinical and brain PET imaging and characterization of the scanner's resolution properties requires measuring its point spread function (PSF). In our previous work we measured the PSF in 2 PET/CT scanners using a printed point source array. Here we extend the work to accurately measure the spatial variation of the PSF on the High Resolution Research Tomograph (HRRT) and assess the impact of the scanner's depth of interaction (DOI) capability on the spatial resolution. Furthermore we characterize the dependency of the PSF to count rate. An array of 15x11 printed sources was scanned twice, initially on its own (10min scan) and subsequently with an extension line containing ∼300MBq of carbon-11 at the scan starts (15 x 10min contiguous frames). Data were reconstructed with OP-OSEM and invariant PSF OP-OSEM. The PSF was found to be radially dependent in all directions but importantly radially symmetric and almost axially independent. The FWHM improves by ∼1.3mm using the PSF-OP-OSEM but is still radially variable with almost 1 mm degradation within the boundaries within which the brain is typically located. When DOI was not taken into account, a degradation up to 0.7mm was seen in the radial FWHM. In terms of count rate dependency, a clear resolution deterioration was seen, for count rates above 5-10 kcps with such count rates observed during many clinical scans.
U2 - 10.1109/NSSMIC.2011.6153675
DO - 10.1109/NSSMIC.2011.6153675
M3 - Conference contribution
AN - SCOPUS:84858651762
SN - 9781467301183
T3 - IEEE Nuclear Science Symposium Conference Record
SP - 3595
EP - 3596
BT - 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011
Y2 - 23 October 2011 through 29 October 2011
ER -