Hydrodynamic Flow Behaviour in Large Diameter Vertical Riser: Experimental and Simulation Studies

Research output: Contribution to conferencePaper

Abstract

An experimental campaign has been performed to investigate the hydrodynamic behaviour in 12m high and 254mm nominal diameter horizontal flowline-vertical riser setup using air-water as working fluid. The data generated from near riser base and flowline pressure variations were used to characterize the stable and unstable flows encountered during the experiments. A model to study the dynamic behaviour of the large diameter horizontal flowline-vertical riser system is developed using OLGA software (v5.1). Experimental results were compared with simulated model. The major objective of undertaking this work is to investigate the performance of the well-known code for flows encountered in large diameter horizontal flowline-vertical riser. Additionally based on the results, also identify the areas of the improvement in the simulator.
Original languageEnglish
Publication statusPublished - 8 Sept 2008
Event11th International Conference on Multiphase Flow in Industrial Plant -
Duration: 9 Aug 2008 → …

Conference

Conference11th International Conference on Multiphase Flow in Industrial Plant
Period9/08/08 → …

Keywords

  • Air-water; Flow patterns; Flow regime transitions; Large diameter; Small diameter; Vertical pipe; Void fraction

Fingerprint

Dive into the research topics of 'Hydrodynamic Flow Behaviour in Large Diameter Vertical Riser: Experimental and Simulation Studies'. Together they form a unique fingerprint.

Cite this