Influence of sidewall restriction on flame length and burning rate of double pool fires in a long-narrow space

  • Mengzhen Liu
  • , Yanfeng Li
  • , Shengzhong Zhao
  • , Kai Du
  • , Wenlong Zhao
  • , Yuan Chen
  • , Mingxuan Qiu
  • , Longyue Li
  • , Yaning Xue
  • , Hua Zhong

Research output: Contribution to journal › Article › peer-review

2 Downloads (Pure)

Abstract

Multiple fire sources in long-narrow spaces such as traffic tunnels, utility tunnels and mine roadways can lead to severe consequences owing to complex flame interactions and restricted ventilation. In particular, wall fire arising from vehicle collisions or leakage alongside gutters represent a critical yet insufficiently quantified scenario. In this study, a 1/10 scale tunnel model was employed to investigate systematically the influence of sidewall restriction on the combustion behaviour and heat transfer mechanism of double pool fires, with emphases on flame shape, flame length and burning rate. The air entrainment capability during double-fire combustion that affected by the enclosure structure of the long-narrow was considered by introducing of modification parameter k and n. A total of 42 experiments were conducted for two typical fire scenarios (centre fire and wall fire), three pool sizes D = 10, 12, and 15 cm and six dimensionless separation distances S/D = 0, 0.5, 1, 1.5, 2, and 3. The results show that, for both scenarios, flame length and burning rate exhibit a non-monotonic dependence on S/D, attaining peak values at S/D = 0.5. Wall-adjacent leak or impact fires in tunnels may produce longer flames, stronger interaction, and higher fuel burning rates than comparable centreline fires. This implies that wall-side scenarios deserve conservative treatment in hazard assessment, detector placement, local structural protection, and emergency response planning. The dimensionless prediction models were developed for flame length and burning rate under varying separation distances and boundary conditions. By comparing with experimental data, it demonstrates that the proposed models could predict the dimensionless flame length and burning rate within ±20% for both centre and wall fire in long-narrow spaces. The findings provide quantitative tools for assessing fire interaction effects and support fire safety design for wall-adjacent scenarios in tunnels and other long-narrow structures.
Original languageEnglish
Article number108340
JournalCase Studies in Thermal Engineering
Volume84
Early online date8 Jul 2026
DOIs
Publication statusPublished - Aug 2026

Cite this