Investigating a Calculation Method for Utot of Window and Shading Systems

Research output: Types of Thesis › MRes Thesis

Abstract

Windows account for 20 to 30 per cent of heat loss through the building envelope during the heating season, yet the thermal contribution of internal shading devices is not credited in UK, European or international building energy standards according to the blind actually fitted. The share depends on glazing ratio, building type and construction; a worked example for a UK dwelling insulated to the 2002 Building Regulations attributes 32 per cent of the heat loss coefficient to windows and doors (Open University, 2018). Standardised methods exist for calculating solar heat gain through glazing with shading (g-total, EN ISO 52022-1), but there is no equivalent method for calculating combined thermal transmittance (U-total) when internal blinds are present. While detailed simulation tools can model shading devices, there is currently no widely adopted simplified standardised method for expressing their contribution as a U-total value suitable for routine compliance calculations and product specification. This absence prevents manufacturers from substantiating thermal performance claims, limits designers to detailed simulation rather than routine calculation, and leaves policymakers without a basis for incorporating window treatments into building regulations. This research develops and tests a practical correction-factor methodology for calculating U-total of glazing systems with internal honeycomb blinds. Highquality empirical data from the University of Salford Energy House facility (George et al., 2025), collected using ISO 9869-1 compliant protocols under controlled steady-state winter conditions, provides the measurement foundation. A key strength of the dataset is that baseline glazing U-values were directly measured in-place rather than assumed from manufacturer specifications, eliminating a common source of uncertainty in window-blind studies. The method applies to honeycomb blinds on low-emissivity double-glazed windows under steady-state winter conditions, at centre-of-glass rather than whole-window level. Its scope is bounded by that of the underlying measurements, and the results below should be read within it. A series thermal resistance model is developed and compared against measurements. The uncorrected series model underestimates the U-total in every configuration examined, and so overstates the thermal benefit of the blind. An empirical correction factor of α = 1.20 is derived and applied to produce the Hybrid Correction Factor Model. The factor is not universal. It is specific to the blind type, mounting arrangement and glazing class from which it was derived, and the external comparisons reported below indicate that its value rises as glazing performance falls. The factor is derived from the two configurations for which the baseline glazing U-value was measured in place on the same unit; three further configurations, whose baseline is assumed rather than measured, serve as a consistency check. Compared against all five, the corrected model returns a Mean Absolute Percentage Error of 3.3% with near-zero systematic bias, against errors of 14 to 21% from the uncorrected calculation. The method is therefore demonstrated on a single well-characterised unit rather than validated across a range. Measured thermal improvements of 30–32% U-value reduction for honeycomb blinds are consistent with literature-reported heat loss reductions. Sensitivity analysis indicates that baseline glazing U-value is the dominant parameter affecting U-total, while blind emissivity, air gap width, and indoor convection conditions have comparatively modest effects. The approach is similar in structure to the simplified g-total method of EN ISO 52022-1, which combines the glazing resistance in series with a fixed coefficient assigned to an internal shading device. The formula applies to honeycomb blinds on low-emissivity double-glazed windows under steady-state conditions. Rough comparison against four published datasets indicates that it does not transfer cleanly to other glazing classes, and that agreement tracks the glazing class more closely than the blind type. Within its demonstrated scope it may be used provisionally in product specification and energy assessment, provided that status is stated. The research establishes a methodological foundation and evidence base upon which future standards development for U-total can be built.
Original languageEnglish
Supervisors/Advisors
  • Andrews, Deborah, Supervisor
  • Gillich, Aaron, Supervisor
DOIs
Publication statusPublished - 2 Oct 2026

Bibliographical note

Project Sponsor: British Blind and Shutter Association (BBSA)

Cite this