Skip to main navigation Skip to search Skip to main content

Performance of six-pulse line-commutated converter in DC motor drive application

  • S.R. ul Hassnain
  • , H. Zaman
  • , Z. Ali
  • , M. Iftikhar
  • , T. Jan

Research output: Contribution to journal › Article › peer-review

Abstract

This paper presents the speed control of DC motor using six pulse controlled rectifier. The conventional Proportional Integral (PI) control is used for firing angle control. The armature current is fed back and compared with reference current representing desired speed values. The proposed system is simulated using SimPowerSystem and Control System Matlab toolbox. The time domain plot of reference and actual armature current are shown in results section. The results are satisfactory with deleterious effect on input current. The frequency plot of input current is provided to show the harmonic contents, generated as a result of control operation.
Original languageEnglish
Pages (from-to)201-208
JournalProceedings of the Pakistan Academy of Sciences
Volume51
Issue number3
Publication statusPublished - 2014

Cite this