Skip to main navigation Skip to search Skip to main content

Reduced acquisition time PET pharmacokinetic modelling using simultaneous ASL–MRI: proof of concept

  • Catherine J. Scott
  • , Jieqing Jiao
  • , Andrew Melbourne
  • , Ninon Burgos
  • , David M. Cash
  • , Enrico De Vita
  • , Pawel J. Markiewicz
  • , Antoinette O'Connor
  • , David L. Thomas
  • , Philip S.J. Weston
  • , Jonathan M. Schott
  • , Brian F. Hutton
  • , Sébastien Ourselin
  • University College London
  • Sorbonne Université
  • University College London Hospitals NHS Foundation Trust
  • St Thomas' Hospital
  • University of Wollongong
  • King's College London

Research output: Contribution to journal › Article › peer-review

14 Citations (Scopus)
4 Downloads (Pure)

Abstract

Pharmacokinetic modelling on dynamic positron emission tomography (PET) data is a quantitative technique. However, the long acquisition time is prohibitive for routine clinical use. Instead, the semi-quantitative standardised uptake value ratio (SUVR) from a shorter static acquisition is used, despite its sensitivity to blood flow confounding longitudinal analysis. A method has been proposed to reduce the dynamic acquisition time for quantification by incorporating cerebral blood flow (CBF) information from arterial spin labelling (ASL) magnetic resonance imaging (MRI) into the pharmacokinetic modelling. In this work, we optimise and validate this framework for a study of ageing and preclinical Alzheimer's disease. This methodology adapts the simplified reference tissue model (SRTM) for a reduced acquisition time (RT-SRTM) and is applied to [18F]-florbetapir PET data for amyloid-β quantification. Evaluation shows that the optimised RT-SRTM can achieve amyloid burden estimation from a 30-min PET/MR acquisition which is comparable with the gold standard SRTM applied to 60 min of PET data. Conversely, SUVR showed a significantly higher error and bias, and a statistically significant correlation with tracer delivery due to the influence of blood flow. The optimised RT-SRTM produced amyloid burden estimates which were uncorrelated with tracer delivery indicating its suitability for longitudinal studies.

Original languageEnglish
Pages (from-to)2419-2432
Number of pages14
JournalJournal of Cerebral Blood Flow & Metabolism
Volume39
Issue number12
DOIs
Publication statusPublished - 1 Dec 2019
Externally publishedYes

Bibliographical note

Publisher Copyright:
© The Author(s) 2018.

Keywords

  • arterial spin labelling
  • cerebral blood flow
  • pharmacokinetic modelling
  • Positron emission tomography
  • reduced acquisition time

Cite this