TY - JOUR
T1 - Theoretical analysis and experimental study on radiative heat flux from adjacent tunnel fires under longitudinal ventilation
AU - Qiu, Mingxuan
AU - Li, Yanfeng
AU - Li, Junmei
AU - Zhong, Hua
AU - Liu, Mengzhen
AU - Li, Yicong
AU - Geng, Zhihao
AU - Liu, Zhiyuan
PY - 2026/10
Y1 - 2026/10
N2 - Fires in tunnels and other confined underground spaces can generate severe radiative heat flux, threatening evacuation and rescue, and increasing the risk of secondary ignition. However, the prediction of radiative heat flux from adjacent fires remains insufficiently understood, particularly when mutual flame occlusion occurs under longitudinal ventilation. This study combines theoretical analysis with experiments to investigate single and adjacent fires under natural and longitudinal ventilation, considering the effects of heat release rate, burner separation distance, and ventilation velocity. Comparison with measurements shows that the conventional point source model substantially overestimates downstream heat flux when flame interaction and ventilation effects are significant. A solid flame radiation model is therefore developed in which the flame is represented as a quadrangular prism derived from observed flame morphology, and an occlusion-aware view factor formulation is introduced for adjacent flames. The proposed model predicts radiative heat flux with acceptable accuracy, with most errors within ±20%. The results further show that increasing longitudinal ventilation velocity raises the peak floor heat flux while reducing the radiation coverage range. These findings provide a useful basis for tunnel fire safety design, risk assessment, and rescue planning in confined underground environments.
AB - Fires in tunnels and other confined underground spaces can generate severe radiative heat flux, threatening evacuation and rescue, and increasing the risk of secondary ignition. However, the prediction of radiative heat flux from adjacent fires remains insufficiently understood, particularly when mutual flame occlusion occurs under longitudinal ventilation. This study combines theoretical analysis with experiments to investigate single and adjacent fires under natural and longitudinal ventilation, considering the effects of heat release rate, burner separation distance, and ventilation velocity. Comparison with measurements shows that the conventional point source model substantially overestimates downstream heat flux when flame interaction and ventilation effects are significant. A solid flame radiation model is therefore developed in which the flame is represented as a quadrangular prism derived from observed flame morphology, and an occlusion-aware view factor formulation is introduced for adjacent flames. The proposed model predicts radiative heat flux with acceptable accuracy, with most errors within ±20%. The results further show that increasing longitudinal ventilation velocity raises the peak floor heat flux while reducing the radiation coverage range. These findings provide a useful basis for tunnel fire safety design, risk assessment, and rescue planning in confined underground environments.
U2 - 10.1016/j.tust.2026.107912
DO - 10.1016/j.tust.2026.107912
M3 - Article
SN - 1878-4364
VL - 176
JO - Tunnelling and Underground Space Technology
JF - Tunnelling and Underground Space Technology
M1 - 107912
ER -